亚洲精品无码一区二区三区久久久,长春欧亚卖场是哪个区,美熟女一区二区三区,亚洲中文字幕无码一区二区三区 ,欧美人与动牲交zooz男人,日本黄h兄妹h动漫一区二区三区,亚洲国产综合久久天堂,四虎成人影视免费在线站长,小黄片午夜视频在线播放,久久久日韩精品一区二区三区

您好,歡迎來到歐亞貿易網!請 |免費注冊

產品展廳本站服務收藏該商鋪

上海碩光電子科技有限公司

免費會員
手機逛
13816422470
上海碩光電子科技有限公司
當前位置:上海碩光電子科技有限公司>>離心機>>臺式大容量離心機>> SG-853automatic balancing large-capacity centrifuge

automatic balancing large-capacity centrifuge

產品二維碼
參  考  價:面議
具體成交價以合同協議為準
  • 產品型號:SG-853
  • 品牌:
  • 產品類別:天平
  • 所在地:
  • 信息完整度:
  • 樣本:
  • 更新時間:2022-12-22 10:32:01
  • 瀏覽次數:6
收藏
舉報

聯系我時,請告知來自 歐亞貿易網

上海碩光電子科技有限公司

其他

  • 經營模式:其他
  • 商鋪產品:1183條
  • 所在地區:
  • 注冊時間:2016-12-12
  • 最近登錄:2022-12-06
  • 聯系人:劉先生
  • 電    話:13816422470

產品簡介

SG-853 automatic balancing large-capacity centrifuge is the company according to the user experience,Carefully design and development of a new generation of centrifuges products

詳情介紹

SG-853 automatic balancing large-capacity centrifuge is  the company  according to the user experience,Carefully design and development of a new generation of centrifuges products, and compared to similar products with higher quality advantage:apply to the hospital laboratory, biochemistry laboratory for qualitative analysis, for plasma, serum, urea, and vaccine manufacturing use. is applicable to all types of laboratory samples of high-capacity centrifugal precision laboratory instruments.
Product features:
1, outstanding performance: micro-computer control, frequency control DC, brushless DC motor without carbon powder pollution;
2, simple: touch panel, digital display, intuitive and reliable;
3, high-capacity multi-rotor, the user easily select

Technical data:
Maximum speed: 5000r/min
No. 1 rotor: 2 *400ml
No. 2 rotor: 4 * 250ml
No. 3 rotor: 36 * 10ml
No. 4 rotor: 72 * 5ml
Motor: Brushless DC Motor
Timing range: 0-99min


Handling Precautions
Work in a high speed centrifuge, used to safety and to ensure that the equipment to maintain high precision work, we must do the following:
1.Centrifuges used to be placed in a smooth, strong on the counter; large-capacity high-speed low-speed centrifuge and refrigerated centrifuge to be placed accordingly on the ground in a solid, level place. Centrifuge work done, the load balancing, weight error as small as possible, otherwise it will cause severe vibration, and shaft damage turned centrifuge.
2.Centrifuge starts, switch knob should be on the low speed position, start and then gradually adjust to the desired value. A work, shall knob again transferred to low-bit work, at high speed block ban on direct start.
3.Rotor in the strict inspection before each use if a foreign body and the dirt hole, in order to maintain balance. Turned around and must be kept dry and clean, do not impact abrasion. Such as accidentally dropped, turned to X-ray film should check that no internal injury can continue to use. Turned after each use with warm water (50 Degrees -60 Degrees) and neutral detergent immersion cleaning, and finally with distilled or deionized water rinse, soft cloth after drying with hair dryer, wax, dry place.
4.Pull all kinds of tube length, strength and stretch are different, should the need to use, the tube can be made of many different materials, such as polyethylene, cellulose, polycarbonates, polypropylene. Use care to ensure the sample, non-corrosive materials, solvent and gradient centrifuge tube and cap components. Expired, the aging, there are cracks or corrosion of the tube by minimizing or spin-down use. Control the use of plastic tube number, pay attention to standard matching. Centrifugal process may open the centrifuge lid, not by hand or foreign body collisions are turned and the rotation of the centrifuge tube.
5. To ensure safety, be sure to use ground wire
6.In the centrifuge process, such as abnormal phenomena, such as the noise and vibration is not normal, should immediay stop checks, not to find reasons not to continue to operate .
7.Daily use of centrifuges in the process, every three months the level of response to host a degree of correction for each transfer using 500 million deal with a vacuum pump oil, working 500h should check drive motor carbon brush, preferably with a vacuum cleaner to friction toner remove, if necessary, to replace carbon brushes or commutator with fine sandpaper polish.Should be cleaned about every driver using the 1500h site with high-speed bearings and grease shaft and turned rust-proof joint of fat should be kept painted, do not be long-term anti-rust oil coating oil paper wrap. When not in use should be switched each month low 1 or 2 times, each time 0.5h, to ensure the normal operation of the site.
8. Be sure to place the centrifuge tube placed symmetrically, and to keep the weight fairly. Things in the open centrifuge to centrifuge lid.
9. Centrifugal liquid should not be too low boiling point,Should pay attention to internal

上一篇: series intelligent mildew incubator
下一篇: large-capacity centrifuge
同類優質產品

在線詢價

X

已經是會員?點擊這里 [登錄] 直接獲取聯系方式

會員登錄

X

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復您~